about news contact support weather driveright marine

















Download Support: Firmware

Click on a title to see more details or to download.

Our Firmware is downloadable at no charge, but requires use of our Vantage Pro Updater for Vantage Pro2 or Vantage Pro Updater for Original Vantage Pro, which are available for purchase through our secure e-commerce system.

If your Vantage Pro2 Console Firmware is dated 28-Nov-05 or later, you may update your console with the Direct PC Install file. This is a stand alone application that will update your console firmware directly through the WeatherLink data logger connected to your PC. (WeatherLink for Vantage Pro2 (#6510SER, 6510USB, 6540, 6544, 6550 or 6560) is required to use the Direct PC Install file.) DO NOT USE the Direct to PC Install file if your Vantage Pro2 firmware revision is dated before November 28, 2005.

WeatherLink for Mac OSX (#6520) does not support Direct PC Install files. To update your console, use a Vantage Pro2 Updater.

Click here for information on updating your firmware and software if you are in a region that uses Daylight Savings Time.

WeatherLink
8/30/2008: WeatherLinkIP Datalogger Firmware, 1.0.4

WeatherLinkIP Datalogger Firmware
Download (300 KB)

Version 1.0.4
1. Resolved a bug that locked up the data logger if a valid DNS could not be found. If a valid DNS cannot be found, the logger will try again every 2 minutes.
2. The displayed units on WeatherLink.com will now match the individual units set on your console. Changes to the unit settings or rain collector size on the console will be immediately uploaded to WeatherLink.com.
3. If the data logger was not able to upload archived data, it will now retry in 5 minutes rather than waiting for the next one-hour upload.

Version 1.0.3
1. Added the capability for updating the console or Envoy firmware through the WeatherLinkIP data logger.
2. Added support for DHCP servers that require the Broadcast flag to be sent.
3. Added a -3º F inside temperature offset to compensate for heat produced by the WeatherLinkIP data logger.
4. Fixed a bug where static IP settings were not always saved through a power cycle.
5. Improved the reliability of the WeatherLinkIP firmware.

Version 1.0.2
Initial WeatherlinkIP data logger firmware release.

Platform:
Version: 1.0.4
File Name: WeatherLinkIP_firmware_v104.exe
File Size: 300 KB
Released: 8/30/2008
5/24/2007: WeatherLink for Irrigation Datalogger Firmware, 2.01

WeatherLink for Irrigation Datalogger Firmware
Download (124 KB)

Firmware version 2.0.1
1. Fixed bug that caused Alarm port to not work when "Delay on Release" and "Delay on Reactivation" values were not set to zero.
2. Changed the smallest irrigation cycle from hour to day.
3. Removed "Rain-ET Threshold", added "Irrigation amount", "Maximum Effective Rain".
4. Fixed problem with resetting values whenever a serial command was received from the PC.

Note: To update your datalogger firmware simply connect your datalogger to your PC. Run this program. Select your COM port number and press OK.

Required: To use these files you MUST HAVE WeatherLink software version 5.7.1 or later, a Davis Vantage Pro or Vantage Pro2 console and a Davis WeatherLink for Irrigation datalogger (#6560).

Platform:
Version: 2.01
File Name: IrrigationFirmwareUpdater_201.exe
File Size: 124 KB
Released: 5/24/2007
3/30/2007: WeatherLink for APRS Datalogger Firmware, 2.02

WeatherLink for APRS Datalogger Firmware
Download (124 KB)

Firmware version 2.0.2
1. Report 2-minte average wind speed and 10-minute high wind speed instead of 1-minute average wind speed and 5-minute high wind speed.
2. Modify Daylight Savings to reflect the new 2007 dates. (Requires the latest console firmware v1.60.)
3. Report altimeter instead of current barometer value.
4. Fixed issue with Daylight Savings in manual mode (this bug requires the latest console firmware version 1.60).
5. Report hourly rain and 24 hourly rain as "000" if both daily rain and storm rain are 0 initially otherwise show "….." in the APRS packet until the measuring time elapses.
6. Add minimum pressure check on the altimeter data.

Note: To update your datalogger firmware simply connect your datalogger to your PC. Run this program. Select your COM port number.Repower your console.When you have confirmation that the updater program has detected your datalogger, then press OK.

Required: To use these files you will need a Davis Vantage Pro Console or Vantage Pro2 Console and a Davis WeatherLink for APRS Datalogger (#6540).

Platform:
Version: 2.02
File Name: APRSFirmwareUpdater_202.exe
File Size: 124 KB
Released: 3/30/2007

Vantage Pro2
6/16/2008: Vantage Pro2 Cabled Console Firmware, Direct PC Install, 1.75a

Vantage Pro2 Cabled Console Firmware, Direct PC Install
Download (460 KB)

NOTE: This firmware is only for Vantage Pro2 Cabled Consoles (#6312C).

Firmware version 1.75a
1. Fixed a compiler bug that would not allow firmware update v1.75 to work properly.

Firmware version 1.75
1. Fixed a bug that causes the console to display incorrect yearly rain values when the unit of measure for rain is set to millimeters.
2. Supports direct updates using USB or TCP/IP connections.

Firmware version 1.73
1. Fixed a bug that gave the High Rain Rate an incorrect time stamp.
2. Fixed a bug that caused an inaccurate barometric reading at high elevation.
3. Extended the amount of time the lamp stays on from 10 seconds to 15 seconds. If a key is pressed within 15 seconds, the lamp stays on for an additional 60 seconds instead of 20 seconds.

Firmware version 1.7, July 2007
1. Fixed a bug that caused the barometric data to spike after a firmware upgrade had occurred.

Platform:
Version: 1.75a
File Name: DirectFromPC_vp2_cabled_1_75a.zip
File Size: 460 KB
Released: 6/16/2008
6/16/2008: Vantage Pro2 Wireless Console Firmware, Direct PC Install, 1.75a

Vantage Pro2 Wireless Console Firmware, Direct PC Install
Download (468 KB)

NOTE: This firmware is only for Vantage Pro2 Wireless Consoles (Davis #6312 or Davis #6312OV).

Firmware version 1.75a
1. Fixed a compiler bug that would not allow firmware update v1.75 to work properly.

Firmware version 1.75
1. Fixed a bug that causes the console to display incorrect yearly rain values when the unit of measure for rain is set to millimeters.
2. Supports direct updates using USB or TCP/IP connections.

Firmware version 1.73
1. Fixed a bug that gave the High Rain Rate an incorrect time stamp.
2. Fixed a bug that caused an inaccurate barometric reading at high elevation.
3. Extended the amount of time the lamp stays on from 10 seconds to 15 seconds. If a key is pressed within 15 seconds, the lamp stays on for an additional 60 seconds instead of 20 seconds.

Firmware version 1.7, July 2007
1. Fixed a bug that caused the barometric data to spike after a firmware upgrade had occurred.
2. The 2ND key function is now enabled longer after being pressed. The timeout period for pressing the 2ND ey and then pressing another 2ND key function was previously 4 seconds but is now 8 seconds.
3. Fixed an issue in handling temperature data when an extra temperature station signal is lost.

Platform:
Version: 1.75a
File Name: DirectFromPC_vp2_wireless_1_75a.zip
File Size: 468 KB
Released: 6/16/2008
6/16/2008: Weather Envoy, Cabled Firmware, Direct PC Install, 1.75a

Weather Envoy, Cabled Firmware, Direct PC Install
Download (448 KB)

NOTE: This firmware is only for a Vantage Pro2 Cabled Weather Envoy (#6316C).

Firmware version 1.75a
1. Fixed a compiler bug that would not allow firmware update v1.75 to work properly.

Firmware version 1.75
1. Fixed a bug that causes the console to display incorrect yearly rain values when the unit of measure for rain is set to millimeters.
2. Supports direct updates using USB or TCP/IP connections.

Firmware version 1.73
1. Fixed a bug that gave the High Rain Rate an incorrect time stamp.
2. Fixed a bug that caused an inaccurate barometric reading at high elevation.

Firmware version 1.7, July 2007
1. Fixed a bug that caused the barometric data to spike after a firmware upgrade had occurred.

Platform:
Version: 1.75a
File Name: DirectFromPC_Envoy2_cabled_1_75a.zip
File Size: 448 KB
Released: 6/16/2008
6/16/2008: Weather Envoy, Wireless Firmware, Direct PC Install, 1.75a

Weather Envoy, Wireless Firmware, Direct PC Install
Download (456 KB)

NOTE: This firmware is only for a Vantage Pro2 Wireless Weather Envoy (#6316 or #6316OV).

Firmware version 1.75a
1. Fixed a compiler bug that would not allow firmware update v1.75 to work properly.

Firmware version 1.75
1. Fixed a bug that causes the console to display incorrect yearly rain values when the unit of measure for rain is set to millimeters.
2. Supports direct updates using USB or TCP/IP connections.

Firmware version 1.73
1. Fixed a bug that gave the High Rain Rate an incorrect time stamp.
2. Fixed a bug that caused an inaccurate barometric reading at high elevation.

Firmware version 1.7, July 2007
1. Fixed a bug that caused the barometric data to spike after a firmware upgrade had occurred.
2. Fixed an issue in handling temperature data when an extra temperature station signal is lost.

Platform:
Version: 1.75a
File Name: DirectFromPC_Envoy2_wireless_1_75a.zip
File Size: 456 KB
Released: 6/16/2008
4/3/2008: Vantage Pro2 Cabled Console Firmware, 1.75

Vantage Pro2 Cabled Console Firmware
Download (467 KB)

NOTE: This firmware is only for Vantage Pro2 Cabled Consoles (#6312C).

Firmware version 1.75
1. Fixed a bug that causes the console to display incorrect yearly rain values when the unit of measure for rain is set to millimeters.
2. Supports direct updates using USB or TCP/IP connections.

Firmware version 1.73
1. Fixed a bug that gave the High Rain Rate an incorrect time stamp.
2. Fixed a bug that caused an inaccurate barometric reading at high elevation.
3. Extended the amount of time the lamp stays on from 10 seconds to 15 seconds. If a key is pressed within 15 seconds, the lamp stays on for an additional 60 seconds instead of 20 seconds.

Firmware version 1.7, July 2007
1. Fixed a bug that caused the barometric data to spike after a firmware upgrade had occurred.
2. The 2ND key function is now enabled longer after being pressed. The timeout period for pressing the 2ND key and then pressing another 2ND key function was previously 4 seconds but is now 8 seconds.

Required: To use these files you will need a Vantage Pro2 Cabled Console and a Davis Vantage Pro2 Firmware Updater (#6311VP2).

Platform:
Version: 1.75
File Name: vp2_cabled_firmware_1_75.zip
File Size: 467 KB
Released: 4/3/2008
4/3/2008: Vantage Pro2 Wireless Console Firmware, 1.75

Vantage Pro2 Wireless Console Firmware
Download (476 KB)

NOTE: This firmware is only for Vantage Pro2 Wireless Consoles (Davis #6312 or Davis #6312OV) and is intended for update using a Vantage Pro2 Updater.

Firmware version 1.75
1. Fixed a bug that causes the console to display incorrect yearly rain values when the unit of measure for rain is set to millimeters.

Firmware version 1.73
1. Fixed a bug that gave the High Rain Rate an incorrect time stamp.
2. Fixed a bug that caused an inaccurate barometric reading at high elevation.
3. Extended the amount of time the lamp stays on from 10 seconds to 15 seconds. If a key is pressed within 15 seconds, the lamp stays on for an additional 60 seconds instead of 20 seconds.

Firmware version 1.7, July 2007
1. Fixed a bug that caused the barometric data to spike after a firmware upgrade had occurred.
2. The 2ND key function is now enabled longer after being pressed. The timeout period for pressing the 2ND key and then pressing another 2ND key function was previously 4 seconds but is now 8 seconds.
3. Fixed an issue in handling temperature data when an extra temperature station signal is lost.

Platform:
Version: 1.75
File Name: vp2_wireless_firmware_1_75.zip
File Size: 476 KB
Released: 4/3/2008
4/3/2008: Weather Envoy, Cabled Firmware, 1.75

Weather Envoy, Cabled Firmware
Download (457 KB)

Note: This firmware is only for a Vantage Pro2 Cabled Weather Envoy (#6316C).

Firmware version 1.75
1. Fixed a bug that causes the console to display incorrect yearly rain values when the unit of measure for rain is set to millimeters.
2. Supports direct updates using USB or TCP/IP connections.

Firmware version 1.73
1. Fixed a bug that gave the High Rain Rate an incorrect time stamp.
2. Fixed a bug that caused an inaccurate barometric reading at high elevation.

Firmware version 1.7, July 2007
1. Fixed a bug that caused the barometric data to spike after a firmware upgrade had occurred.

Required: To use these files you will need a Davis Weather Envoy (#6316C) and a Davis Vantage Pro2 Firmware Updater (#6311VP2).

Platform:
Version: 1.75
File Name: Envoy2_cabled_firmware_1_75.zip
File Size: 457 KB
Released: 4/3/2008
4/3/2008: Weather Envoy, Wireless Firmware, 1.75

Weather Envoy, Wireless Firmware
Download (465 KB)

NOTE: This firmware is only for a Vantage Pro2 Wireless Weather Envoy (#6316 or #6316OV).

Firmware version 1.75
1. Fixed a bug that causes the console to display incorrect yearly rain values when the unit of measure for rain is set to millimeters.

Firmware version 1.73
1. Fixed a bug that gave the High Rain Rate an incorrect time stamp.
2. Fixed a bug that caused an inaccurate barometric reading at high elevation.

Firmware version 1.7, July 2007
1. Fixed a bug that caused the barometric data to spike after a firmware upgrade had occurred.
2. Fixed an issue in handling temperature data when an extra temperature station signal is lost.

Required: To use these files you will need a Davis Weather Envoy (#6316 or #6316OV) and a Davis Vantage Pro2 Firmware Updater (#6311VP2).

Platform:
Version: 1.75
File Name: Envoy2_wireless_firmware_1_75.zip
File Size: 465 KB
Released: 4/3/2008
2/15/2006: Vantage Pro2 Updater Firmware, 02/2006

Vantage Pro2 Updater Firmware
Download (239 KB)

NOTE: This is not Vantage Pro2 console firmware and should not be used to upgrade your Vantage Pro2 console. This file only updates the firmware in a Vantage Pro2 Updater (Davis #6311VP2).

This February 7, 2006 firmware update has the following changes -
1. Corrects a problem that may cause the Updater to not update a Vantage Pro2 console. The Updater may show a red light and halt.

The December 1, 2005 firmware release has the following changes -
1. In order for the "direct from PC firmware update" feature of the Nov, 2005 console firmware to be properly implemented, the Updater must have this latest Updater firmware in it prior to updating a VP2 console.
2. With this Updater firmware, future Updater firmware can be programmed to the Updater directly from a PC without the use of a second Updater.

Required: To use this file you will need at least two Vantage Pro2 Updaters (Davis #6311VP2).

Platform:
Version: 02/2006
File Name: vp2_updater_2-7-06.zip
File Size: 239 KB
Released: 2/15/2006

Vantage Pro
3/5/2007: Vantage Pro Console Firmware (Nov. 2006), Rev. B

Vantage Pro Console Firmware (Nov. 2006)
Download (691 KB)

Firmware version Nov 20, 2006
1. Now supports new daylight savings time dates.
2. External software can now detect if the console is on daylight savings time or not when in "auto detect" mode.
3. Fixed non flashing graph point. (last dot)

Firmware version Mar 30, 2004
1. Fixes RF range and performance issues in a small percentage of consoles manufactured between March 2003 and March 2004. This was caused by different wakeup characteristics of the newer microprocessor and a variance in receiver chips.

This zip file contains 4 files.
1. flash.bin - Firmware release.
2. updater.exe - Program required to load firmware into the Davis Updater (Davis #6311).
3. Vantage Console Firmware Release History.doc - details on each firmware revision.
4. vp_updater.pdf - Instructions (see Section 2: Advanced Operations).

Required: To use these files you will need a Davis Vantage Pro console and a Davis Vantage Pro Firmware Updater (Davis #6311VP1).

Platform:
Version: Rev. B
File Name: vp_firmware_11-20-06.zip
File Size: 691 KB
Released: 3/5/2007
3/5/2007: Weather Envoy Firmware, 11/2006

Weather Envoy Firmware
Download (685 KB)

NOTE: This firmware is only for a Vantage Pro Wireless Weather Envoy (Davis #6314, Davis #6314OV or Davis #6314C).

Firmware version Nov 20, 2006
1. Now supports new daylight savings time dates.
2. External software can now detect if the console is on daylight savings time or not when in "auto detect" mode.

Firmware version Mar 30, 2004
1. Fixes RF range and performance issues in a small percentage of consoles manufactured between March 2003 and March 2004. This was caused by different wakeup characteristics of the newer microprocessor and a variance in receiver chips.

This zip file contains 4 files.
1. flash.bin - Firmware release.
2. updater.exe - Program required to load firmware into the Davis Updater (Davis #6311).
3. Vantage Console Firmware Release History.doc - details on each firmware revision.
4. vp_updater.pdf - Instructions (see Section 2: Advanced Operations).

Required: To use these files you will need a Davis Weather Envoy and a Davis Vantage Pro Firmware Updater (Davis #6311VP1).

Platform:
Version: 11/2006
File Name: envoy_firmware_11-20-06.zip
File Size: 685 KB
Released: 3/5/2007
4/5/2004: Updater Firmware (Mar. 2004), Rev. B

Updater Firmware (Mar. 2004)
Download (128 KB)

This firmware release has the following changes -
1. Allows an Updater to load console firmware into all versions of Vantage Pro. Prior to this release of Updater code a rev A Updater could only update Vantage Pro consoles manufactured prior to March 2003.

NOTE: This is not Vantage Pro console firmware and should not be used to upgrade your Vantage Pro console firmware.

Required: To use this file you will need at least two Davis Firmware Updaters (Davis #6311).

Platform:
Version: Rev. B
File Name: flash.bin
File Size: 128 KB
Released: 4/5/2004
3/21/2003: Vantage Pro Console Firmware (Spanish, 7/25/2002), Rev. B

Vantage Pro Console Firmware (Spanish, 7/25/2002)
Download (686 KB)

This is a version of Vantage Pro firmware that will display text in Spanish.

This zip file contains 4 files.
1. flash.bin - Firmware release.
2. updater.exe - Program required to load firmware into the Davis Updater (Davis #6311)
3. Vantage Console Firmware Release History.doc - details on each firmware revision.
4. vp_updater.pdf - Instructions (see Section 2: Advanced Operations)

Required: To use these files you will need a Davis Vantage Pro console and a Davis Firmware Updater (Davis #6311)

Platform:
Version: Rev. B
File Name: vp firmware 7-25-02 spanish.zip
File Size: 686 KB
Released: 3/21/2003